Measuring principle
Capacitive Liquid
Characteristic / Application
Capacitive rod probe
Specialities
Interface detection
Foam detection
Ambient temperature
-50 °C ... +70 °C
(-58 °F ... +158 °F)
With separate housing:
-50 °C ... +120 °C
(-58 °F ... +248°F)
Process temperature
-80 °C ... +200 °C
(-112 °F ... +392 °F)
Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vacuum ... 1450 psi)
Main wetted parts
Insulation material: PTFE, PFA
316L
Process connection
G 1/2 ... 1 1/2
NPT 1/2 ... 1 1/2
Flange from DN25.../ASME 1".../JIS 10K...
Process connection hygienic
Tri-Clamp ISO2852 gap free plated
Dairy coupling
Flush mount
Sensor length
Total length of probe: max 6 m (20 ft)
Communication
2- wire 19-253 VAC
3-wire
PFM
Relay DPDT
DC-PNP
8/16 mA
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvals
Overfill prevention WHG
SIL
Design approvals
EN 10204-3.1
NACE MR0175
Marine approval
GL/ ABS/ DNV
Options
Inactive length
Fully isolated active build-up compensation
Ground tube
Separate housing
Components
Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire:
FTC325
Application limits
Notice the pressure and temperature derating.
Notice for non conductive medium the DK.
Delivery: |
UPS, FedEX and DHL
International delivery available
Same day shipping for in-stock on location
Will negotiate shipping details |
Combined Shipping Policy: |
We will combine shipments to reduce costs for customers purchasing multiple items.
After customers have completed their mulitple purchases they should request an invoice.
We will package and weigh the entire purchase and provide an invoice, including shipping and handling. |
Warranty: |
All of our products are covered by REEMAN
We will take test video before shipping
✓ 30 day Warranty - Refurbished Parts |
Returns: |
No hassle return policy. |
Quick Quotes: |
Receive Price & Availability Today! |
Payment: |
|