Type : Electromagnetic flowmeter
Model : OPTIFLUX 2100C
Order code of flow sensor : VN1446501303113001000000000
Order code of signal converter : VN3104A0660010100000
Type OPTIFLUX 2100 C Primary head OPTIFLUX 2000
Compact model
Meter size : DN 40 / 1 1/2"
Connection : DN 40 PN 40
Mounting length : 200 mm / 7.87" - ISO 13 359 excl.gaskets & rings
Flange material : steel 1.0460 (C 22.8)
Housing : Sheet metal
Lining : Polypropylene
Fluid temperature : max. 90 °C / 194 °F. depending on pressure.
Electrodes : Hastelloy C4 fixed electrodes with 2 electrodes construction
Insulation class of coi : H
Protection class : IP 66/67 (NEMA 4X/6) acc. EN 60 529
Installation instruction : multi-language
Tagplate : 67 x 25 mm / 2.64 x 0.98"
Material : 304 / 1.4301
Tagno. : see calibration data
Calibration : GKL
PED group 1 - liquids
SEP
APPLICATION DATA
medium : cooling water
temperature : 35 °C
pressure : 10 bar
measured range : 0 ... 22 m³/h
tag no. : HC11 FT 212111
tag no. : HC11 FT 212121
KROHNE flow converter
Type : IFC 100 C
Compact model (0°)
Empty pipe detection, conductivity
Incl. software : PACTWARE
Accuracy : +/- 0,3% v MV see TDS
Power supply : 100-230 V AC, 50/60 Hz (85-250 V)
Cable connection : 2 x M20 x 1,5
Operation manual : Without
Programming : English
Process diagnostic : Standard
Gas content, function of electrodes,
temperature.
Converter housing : Standard, aluminum
Communication : Basic I/O
1. Current output : HART, active / passive
2. Pulse / status outp. : passive
3. Status output : passive
APPLICATION DATA
puls output 1 : 10 Imp/m3
current output 1 : 4 ... 20 mA
display : m3/h
Material Certificate
Type of instrument : Aquaflux / OPTIFLUX 2000
Process connection : Flange
For : Flange/tube/electrode/electrodebush
Meter size : Standard according to manual DN10-3000 - 3/8"-120"
Range of test : Without
Certificate : WB 2.1
Language : Standard (GE/EN/FR)
Supervision : Without
*** 3 x instrument to be sent to KIT separately
Calibration
Type of instrument : Standard according manual
Meter size : DN25-150 - DN1"-6"
Range of test : Standard
Specification : Standard
Acceptance criteria : Standard
Certificate : Standard
Language : English
Supervision :Without
Delivery: |
UPS, FedEX and DHL
International delivery available
Same day shipping for in-stock on location
Will negotiate shipping details |
Combined Shipping Policy: |
We will combine shipments to reduce costs for customers purchasing multiple items.
After customers have completed their mulitple purchases they should request an invoice.
We will package and weigh the entire purchase and provide an invoice, including shipping and handling. |
Warranty: |
All of our products are covered by REEMAN
We will take test video before shipping
✓ 30 day Warranty - Refurbished Parts |
Returns: |
No hassle return policy. |
Quick Quotes: |
Receive Price & Availability Today! |
Payment: |
|